DN: 1/8"–1"
PN: 1.5 MPa
t max°: 180°С
Body material: brass
Connection: threaded
Medium: water, steam (up to 180 °C), air and other media neutral to the materials of the valve construction
Safety function: normally closed (NC) - ESK 203 series and normally open (NO) - ESK 204 series
Number of strokes: 2/2 (ports/nozzles)
Pressure ranges: 1–10 bar
Mediate temperature: -10 °C … +180 °C
Ambient temperature: -20 °C – +70 °C
Opening time: 200-1500 ms
Closing time: 500-2000 ms
Maximum allowable pressure: 15 bar
Required minimum differential pressure: 1 bar
Valve seal: O-rings
Voltage: AC, DC
Rearrangement of the coil without dismantling the valve (regardless of AC, DC)
Installation in any position, but the best position is with the coil facing up
The medium must be filtered before the valve
The flow rate (Q) can be calculated based on the pressure, density and flow coefficient
In accordance with 97/23/EC Pressure Equipment Directive (PED), 2006/95/EEC Low Voltage Directive (LVD), 2004/108/EC Electromagnetic Compatibility Directive (EMC)